FIRE PROTECTION

Fire-protective coating for exterior wood: what a Class A rating means and where it fits

A Class A surface-burning rating means the coated material landed in the lowest flame spread band of the ASTM E84 tunnel test. It reduces how fire spreads across the surface; it does not make wood fireproof or non-combustible.

Prepared by NanoGuard SolutionsLast reviewed ·
Class A0–25Class B26–75Class C76–200Coating tested: flame spread 0Flame spread index
Diagram · ASTM E84 flame spread classes (bands not drawn to scale)

What ASTM E84 measures

ASTM E84 is a tunnel test that records two numbers for a material's surface: a flame spread index, for how far and fast flame travels across it, and a smoke-developed index, for how much smoke it gives off.

Class A is the band for a flame spread index of 0 to 25, with the smoke-developed index limited to 450 or less. The coating NanoGuard installs tested Class A, with a flame spread index of 0 and a smoke-developed index of 0.

Other tests behind it

The coating has also been run through these tests:

  • ASTM E119: fire resistance, or how long a building assembly holds up under a standard fire exposure.
  • ASTM E162: surface flammability measured against a radiant heat panel.
  • ASTM E662: the density of smoke a solid material produces.

Other standards it has been tested to:

  • ASTM G124

How it's applied

It goes directly onto the wood. No primer or topcoat is used, because either can raise flammability.

The film is non-sacrificial: there is no intumescent swelling and no charring step. If flame reaches it, the coated area is inspected afterwards and recoated wherever the film was damaged.

Warranty

The coating carries a 10-year manufacturer materials warranty. Installation labour is the applicator's responsibility, not the manufacturer's.

Where it fits

Typical uses are utility poles, timber retaining and lagging walls, bridge and overpass timbers, fencing, boardwalks and trail structures, and park signage. Field examples are on the fire protection page.

What it isn't

It is not a substitute for code-required fire separations or for a fire engineer's design.

Your next step

Send photos of the structure, what the wood is and how it is finished now, and roughly how much area needs coating. We will assess it on site and come back with a scope.

Questions

Does a fire-protective coating make wood fireproof?

No. It changes how flame spreads across the surface of the wood; the wood underneath is still combustible.

Can it go over painted or stained wood?

The coating is applied without primers or topcoats, so any existing finish is assessed on site before we quote.

What happens after a fire touches it?

The affected area is inspected, and any section where the film was damaged is recoated.

Request a technical reviewCall